Heat Exchanger & Cold Plate Cleaning Services | CXP Solutions
Thermal Performance Restoration

Heat Exchanger & Cold Plate Cleaning

Fouling reduces thermal efficiency by 30-70%, costing facilities thousands in wasted energy monthly. CXP's mobile chemical cleaning systems restore heat exchanger performance on-site—no equipment removal, no extended downtime.

95% Efficiency

After CXP cleaning, heat exchangers typically recover 95%+ of original thermal efficiency—documented with pre/post performance testing.

📊1/16" scale = 11% efficiency loss (DOE)
💰Fouling costs US industry $14B+ annually
🔥0.5mm biofilm reduces heat transfer 30%
Heat exchangers = 30% of industrial energy use
🏭Proper cleaning extends equipment life 3-5 years
❄️Data center cooling = 40% of facility power
📊1/16" scale = 11% efficiency loss (DOE)
💰Fouling costs US industry $14B+ annually
🔥0.5mm biofilm reduces heat transfer 30%
Heat exchangers = 30% of industrial energy use
The Fouling Problem

Why Heat Exchangers Lose Performance

Scale, biofilm, and particulate accumulation create thermal barriers that waste energy, increase costs, and risk equipment failure.

🔥
0
% Efficiency Loss
Maximum thermal reduction from severe mineral scale buildup
💵
$0
Annual US Cost
Industry-wide losses from fouling-related inefficiency
⏱️
0
Hour Turnaround
Typical on-site cleaning cycle with full documentation
0
Efficiency Restored
Typical performance recovery after chemical cleaning
📚 Sources: US Department of Energy, ASHRAE, Heat Transfer Research Inc. | Calculate your system's flow requirements →
Equipment We Service

Heat Exchanger & Cold Plate Types

Mobile cleaning solutions for every heat transfer application—from GPU cold plates to industrial shell-and-tube units.

📋

Plate Heat Exchangers

Gasketed plate systems for data center chilled water, process cooling, and HVAC applications. Chemical circulation with optional disassembly.

Alfa Laval SWEP APV
🔩

Brazed Plate HX

Compact brazed plate units common in precision cooling. Specialized in-place cleaning without disassembly—critical for sealed units.

Compact No Gaskets CIP Clean
🌀

Shell & Tube

Industrial workhorses for cooling towers, chillers, and process utilities. Chemical and mechanical tube cleaning available.

Tube Bundles Shell Side Both Sides
💻

GPU Cold Plates

Microchannel cold plates for AI servers and HPC systems. Ultra-clean chemical circulation to prevent catastrophic blockage. See our cold plate protection guide.

50-200μm Precision Filtered
🚪

Rear-Door Heat Exchangers

Active rear-door cooling for high-density server racks. On-site flushing without rack removal. Related: RDHx flushing services.

In-Situ No Removal Live Racks

CDU Heat Exchangers

Coolant distribution unit exchangers for liquid cooling loops. Precision cleaning with microchannel protection protocols.

Facility Rack-Level Server
💊

Pharma Heat Exchangers

GMP-compliant cleaning for pharmaceutical and biotech applications. Full documentation for validation.

GMP Validated Documented
❄️

Condensers & Evaporators

HVAC condensers, chiller evaporators, and refrigeration systems. Scale removal and thermal restoration.

Chillers AHU Coils DX Systems
Scroll to explore all equipment types
Interactive Tool

Fouling Impact Calculator

See how scale buildup affects your thermal efficiency and energy costs. Based on DOE thermal conductivity research.

⚙️ Adjust Parameters

Scale Thickness 1/32"
Monthly Energy Cost $10,000
HX % of Cooling Load 40%

📊 Note: This calculator uses DOE thermal resistance data for calcium carbonate scale. Actual losses vary by scale composition and heat exchanger design.

📉 Estimated Impact

-5%
Thermal Efficiency Loss
$200
Monthly Waste
$2,400
Annual Waste

Cleaning typically costs 5-15% of annual waste savings

Get Cleaning Quote

Need precise calculations? Try our Flow Rate Calculator or Piping Volume Calculator

Field Work

Heat Exchanger Cleaning in Action

Real projects from data centers, pharmaceutical facilities, and industrial plants.

Corrosion on heat exchanger tubes
Corroded heat exchanger tubes requiring chemical cleaning
Air-cooled chiller system
Air-cooled chiller with associated heat exchangers
Chiller disassembly for cleaning
Chiller heat exchanger disassembly for inspection
Cooling tower system
Cooling tower system with associated heat exchangers
Stainless steel piping and valves
Stainless process piping feeding heat exchangers
Engineer monitoring flow rate
Flow rate monitoring during cleaning circulation
Expert Knowledge

The 5 Types of Heat Exchanger Fouling

Understanding fouling mechanisms is essential for prevention and treatment selection. Click each card to learn more.

💎

Crystallization

Mineral scale deposits

Click to flip

Crystallization Fouling

Dissolved minerals (CaCO₃, CaSO₄, silica) precipitate when solubility limits are exceeded at heated surfaces. Scale acts as thermal insulation—just 1/32" reduces efficiency by 5-8%.

30-70% Efficiency loss from severe scale
Calculate cleaning chemistry →
🔩

Particulate

Debris & suspended solids

Click to flip

Particulate Fouling

Suspended solids (construction debris, corrosion products, sand) settle in low-velocity zones. Microchannels in GPU cold plates can block completely with particles >50μm.

50-200μm Cold plate channel width at risk
High-velocity flushing services →
🦠

Biological

Biofilm & microbial growth

Click to flip

Biological Fouling

Bacteria, algae, and fungi form protective biofilm matrices. Biofilm traps nutrients, accelerates growth, and creates oxygen-depleted zones that cause under-deposit corrosion.

0.5mm Biofilm reduces heat transfer 30%
Biofilm removal guide →
⚗️

Chemical Reaction

Polymerization & oxidation

Click to flip

Chemical Reaction Fouling

Heated surfaces catalyze chemical reactions—oils polymerize, glycol degrades to acids, phosphates precipitate from overtreated water. These deposits are often hardest to remove.

160°F+ Accelerates reaction fouling
Chemical cleaning services →
🔶

Corrosion

Oxide & rust deposits

Click to flip

Corrosion Fouling

Corrosion products (iron oxide, copper oxide) accumulate and trap additional debris. Self-propagating: deposits create oxygen-depleted zones causing more corrosion underneath.

Rouge Iron oxide accumulation in SS systems
Derouging services →
Our Process

Heat Exchanger Cleaning Protocol

Six-phase chemical cleaning process for maximum thermal restoration with documented verification.

1

Baseline Testing

Thermal performance measurement, pressure drop testing, and fouling assessment before cleaning.

⏱️ 1-2 hrs 📋 Data logged
2

Alkaline Degrease

Heated caustic circulation (140-180°F) removes oils, biofilm, and organic contamination.

🌡️ 140-180°F ⏱️ 2-4 hrs
3

Acid Descale

Citric, EDTA, or phosphoric acid dissolves mineral scale without attacking base metal.

⚗️ pH 1.5-4.0 ⏱️ 2-6 hrs
4

Neutralization

pH adjustment to 6.5-7.5 prevents flash corrosion and prepares for final rinse.

⚖️ pH 6.5-7.5 ⏱️ 30-60 min
5

High-Purity Rinse

DI/RO water flush to <2 μS/cm conductivity, removing all chemical residue.

💧 <2 μS/cm ⏱️ 1-2 hrs
6

Verification & Docs

Post-cleaning thermal testing, efficiency comparison, and complete documentation package.

📊 Before/After 📁 Full report
Industry Intelligence

What Every Facility Manager Should Know

Critical heat exchanger facts backed by DOE research, ASHRAE standards, and field experience.

01

Scale Thickness = Energy Waste

According to the US Department of Energy, calcium carbonate scale causes measurable efficiency loss at surprisingly thin layers:

  • 1/32" scale = 5-8% efficiency loss
  • 1/16" scale = 11% efficiency loss
  • 1/8" scale = 20% efficiency loss
  • 1/4" scale = 39% efficiency loss
Source: DOE Industrial Heat Exchanger Performance Guide
02

Data Center Cooling = 40% of Power

Cooling infrastructure consumes the largest share of non-IT power in data centers. Heat exchanger efficiency directly impacts PUE (Power Usage Effectiveness):

  • Typical PUE: 1.5-2.0 (50-100% overhead)
  • Best-in-class PUE: 1.1-1.2
  • Each 0.1 PUE improvement = ~$100K/year savings per MW
Source: ASHRAE TC 9.9, Uptime Institute
03

Biofilm: The Hidden Threat

Biofilm fouling is more insidious than mineral scale because it's often invisible until severe. Key facts:

  • Biofilm thermal conductivity: 0.6 W/m·K (vs. steel: 50 W/m·K)
  • 0.5mm biofilm reduces heat transfer by 30%
  • Biofilm harbors Legionella and other pathogens
  • Creates MIC (Microbiologically Influenced Corrosion)
Source: Heat Transfer Research Inc., CDC
04

GPU Cold Plate Sensitivity

AI server cold plates have microscopic channels that make them extremely vulnerable to particulate fouling:

  • Channel width: 50-200 μm (thinner than human hair)
  • Single blocked channel = hotspot formation
  • Particle threshold: 5-10 μm filtration required
  • Recovery from blockage: Often impossible without replacement
05

Cleaning ROI: Typical Payback

Professional heat exchanger cleaning delivers rapid return on investment through energy savings and equipment protection:

  • Typical cleaning cost: $2,000-15,000 per unit
  • Energy savings: 15-40% of cooling costs
  • Typical payback: 3-12 months
  • Equipment life extension: 3-5 years
Based on CXP field data and industry benchmarks
06

Warning Signs: When to Clean

Don't wait for complete failure. These indicators signal the need for professional heat exchanger cleaning:

  • Approach temperature +5-10°F from baseline
  • Pressure drop +25-50% from design
  • Energy consumption +20-40% vs. normal
  • Visible deposits during inspection
Results

Before & After Cleaning

Drag the slider to see the difference professional cleaning makes.

Contaminated fitting before cleaning Clean fitting after derouging treatment
Before
After
🔥
95%+
Thermal Efficiency Restored
📉
-40%
Pressure Drop Reduction
-25%
Energy Consumption
📅
+3-5yr
Equipment Life Extension
FAQ

Heat Exchanger Cleaning Questions

Cleaning frequency depends on water quality, system design, and fouling rate. Most facilities benefit from annual cleaning, but monitoring approach temperature and pressure drop provides the best guidance. A 5°F increase in approach temperature or 25% increase in pressure drop signals cleaning is needed regardless of schedule. Contact us for a site assessment.

Yes, our mobile CIP (Clean-In-Place) systems connect directly to heat exchangers for on-site chemical circulation. This eliminates the need for removal, reduces downtime, and avoids the risk of damage during transportation. We can clean plate, brazed plate, shell-and-tube, and most other heat exchanger types in place. Some severe cases may require disassembly for mechanical cleaning.

Chemical selection depends on fouling type and heat exchanger metallurgy. For scale removal, we use citric acid (preferred for stainless steel), EDTA (chelating agents for complex scale), or phosphoric acid. For biological and organic fouling, we use heated alkaline cleaners. All chemicals are selected for material compatibility and followed by complete neutralization and rinsing. See our Chemical Dilution Calculator for more details.

Typical cleaning cycles take 8-24 hours depending on fouling severity and heat exchanger size. This includes setup, chemical circulation (2-6 hours per phase), neutralization, high-purity rinsing, and verification testing. Most projects complete within 48 hours total, including documentation. Emergency service available for critical systems.

Yes, every project includes a complete documentation package: baseline testing results, cleaning procedures used, chemical concentrations and contact times, neutralization verification, final rinse water quality (conductivity, pH), before/after performance comparison, and photos. For pharmaceutical and GMP applications, we provide additional documentation per GMP requirements.

Yes, we specialize in cleaning and commissioning liquid-cooled AI/HPC infrastructure. GPU cold plates have extremely narrow microchannels (50-200μm) that require specialized low-pressure chemical circulation with stringent filtration to prevent blockage. We follow strict cold plate protection protocols and microchannel-safe procedures to avoid catastrophic damage.

Get Started

Need Heat Exchanger Cleaning?

CXP Solutions provides mobile heat exchanger cleaning with documented thermal performance restoration. On-site service, complete documentation, and owner-led execution on every project.

🚚 Mobile CIP Systems
📋 Complete Documentation
👤 Owner on Every Job
48hr Turnaround

Request a Quote